1. <center></center>

                1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

                  LCD type vortex flowmeter

                  5卡裝(zhuang)式(shi)渦街流(liu)量計(液(ye)晶(jing)型).PNG
                  • 5卡裝(zhuang)式(shi)渦(wo)街流(liu)量(liang)計(液(ye)晶型).PNG
                  LCD type belongs to the fluid vibration flowmeter, vortex flowmeter can be used for measurement of s…

                  Description:

                  Products overview:
                  ZW - LUGB seriesLCD type vortex flowmeterIs according to the principle of Carmen (Karman vortex street research production, mainly used in industrial pipeline medium fluid flow measurement, such as gas, liquid, steam and other media.Is characterized by small pressure loss, wide range, high precision, working condition of the measurement volume flow is almost not affected by the fluid density, the influence of the parameters such as pressure, temperature, viscosity.No moving mechanical parts, so high reliability, small amount of maintenance.Instrument parameters can be long-term stability.Vortex street flowmeter using piezoelectric stress sensor, high reliability, can be in - 20 ℃ ~ + 250 ℃ temperature range.There are standard signal simulation and digital pulse signal output, easy with the computer and digital systems, is a more advanced, the ideal measuring instrument.
                  Second, the working principle:
                  ZW - LUGB series LCD type measuring principle of vortex flowmeters is by the design, testing probe in the flow field in the vortex body and the corresponding electronic circuit, etc.When the fluid flows through the spiral body occurs, it is formed on both sides of the two rows of vortex variations, this vortex is known as the karman vortex street.On the basis of the theory of karman vortex street and proposed the karman vortex street frequency is proportional to the velocity of the fluid, the relation between the frequency and velocity are presented: f = St * V/d type:
                  F vortex frequency (Hz)
                  V vortex occurred body on both sides of the average flow velocity (m/s)
                  St, luo hall coefficient (constant)
                  These variations of vortex is formed a series of variations of negative pressure, the pressure on detecting probe, and produce a series of alternating electric signals, after dealing with the preamplifier conversion, plastic, amplification, the output is proportional to the vortex synchronous pulse frequency signal (or standard).
                  Applications: 
                  ZW - LUGB series LCD type vortex flowmeter is widely used in petroleum, chemical industry, metallurgy, machinery, paper, and the city pipe heating, water supply, gas and other industries of all kinds of low viscosity liquid, gas, steam, etc of single-phase fluid process measurement and energy saving management.

                  Four, the main features:
                  1, can accurately measure within wide flow range of gas, liquid and steam flow and not affected by fluid physical properties;
                  2, not affected by temperature, pressure, not easy to plug at the same time, not easy card, not easy to scale, high temperature resistant, high voltage;
                  3, safety explosion-proof, suitable for bad environment;
                  4, have no moving parts, no hole aperture design, product without any abrasion, corrosion resistance, dirt without mechanical maintenance, long service life;
                  5, using micro power consumption of new and high technology, a battery-powered scene shows type flowmeter, power is not running for more than two years;
                  6, temperature, pressure compensation integrated design;
                  7, current output are electrical isolation, good common-mode interference suppression ability;
                  8, also showed flow values and cumulative flow value, don't have to take turns to switch;
                  9, using vibration probe, the effective elimination of the influence of external vibration;
                  10, using split type signal converters, cable is 100 meters long;
                  11, than a wide range of those days;
                  12, instrument structure design is reasonable, wide dynamic range, small pressure loss;
                  13, table body is made of stainless steel material, can be applied to measurements of corrosive medium;
                  14, the liquid crystal display, pulse, 4 ~ 20 ma output 485 newsletter, or can be connected to the industrial automation system.
                  Five, the technical parameters:
                  1, the measured medium: gas, liquid and vapor;
                  2, connection mode: flange card mounted, flange, plug-in;
                  3, diameter specifications flange mounted caliber select 25,32,50,80,100;
                  4, the flange connection type choose 100150200;
                  5, flow range (see chart flow range)
                  6, normal measuring velocity range Reynolds number 104 ~ 1.5 x 4 x 106;Gas 5 to 50 m/s;Liquid 0.5 ~ 7 m/s;
                  7, measurement accuracy 1.0 magnitude 1.5 on the Richter scale;
                  8, measured medium temperature: room temperature - 25 ℃ ~ 100 ℃, high temperature - 25 ℃ ~ 150 ℃ to 25 ℃ ~ 250 ℃;
                  9, high output signal pulse voltage output signal level 8 ~ 10 V low level from 0.7 V to 1.3 V;
                  10, pulse duty ratio is about 50%, transmission distance is 100 m;
                  11, pulse current 4 ~ 20 mA remote transmission signal, transmission distance is 1000 m;
                  12, instrument: using the environment temperature 25 ℃ ~ + 55 ℃, humidity: 5 ~ 90% RH50 ℃;
                  13, the material of stainless steel, aluminum alloy;
                  14, DC24V power supply or lithium battery 3.6 V;
                  15, explosion-proof grade this Ann model iaIIbT3 - T6, protective class IP65.

                  Six, appearance size:

                  DN

                  A

                  B

                  C

                  D

                  15

                  90

                  Φ 57

                  383

                  45

                  20

                  100

                  Φ 57

                  388

                  50

                  25

                  100

                  Φ 57

                  394

                  50

                  32

                  100

                  Φ 65

                  396

                  50

                  40

                  100

                  Φ 75

                  401

                  50

                  50

                  110

                  Φ 87

                  407

                  55

                  65

                  110

                  Φ 109

                  418

                  55

                  80

                  110

                  Φ 120

                  423

                  55

                  100

                  120

                  Φ 149

                  447

                  60

                  125

                  125

                  Φ 175

                  474

                  65

                  150

                  145

                  Φ 203

                  501

                  75

                  200

                  170

                  Φ 259

                  556

                  100

                  250

                  190

                  Φ 312

                  608

                  120

                  300

                  210

                  Φ 363

                  660

                  140

                  350

                  230

                  Φ 409

                  709

                  160

                  400

                  250

                  Φ 460

                  756

                  180

                  450

                  275

                  Φ 520

                  814

                  205

                  500

                  290

                  Φ 575

                  869

                  225

                  Seven, pipe requirements:
                  1, the requirement for straight pipe:
                  In order to ensure that the instrument, accurate to run normally, sensor must have a certain straight pipe upstream and downstream of the installation points, to adjust the flow field, as shown.

                  Figure 1: concentric contraction tube;
                  Figure 2: the concentric expansion tube;
                  Figure 3: a 90 - degree Angle;
                  Figure 4: the same plane of two 90 - degree Angle;
                  Figure 5: different plane of two 90 - degree Angle;
                  Figure 6: regulating valve should be installed downstream of the sensor in 5 d to the distance, if the sensor must be installed in the upstream, the sensors should be not less than 50 d upstream, straight pipe section downstream straight pipe section should be not less than 5 d.
                  2, the requirement of pipe:
                  A, upstream and downstream piping diameter D and the same as the sensor inner diameter DN, its difference satisfy the following conditions: 0.95 DN D 1.1 or less or less DN.
                  B, piping shall be concentric with sensor, coaxial degree should be less than 0.05 DN.
                  C, gasket not protruding into the pipe, the inner diameter slightly larger than sensors.
                  D, if you want to stop inspection and cleaning the sensor, the by-pass pipe should be set up,As shown in the figure below.

                   
                  3, the requirement of pipe vibration:
                  Sensors to avoid installed on the strong pipeline vibration, if necessary to install, shock absorption measures must be taken, respectively at the upstream and downstream of sensor 2 d piping fastening device, and vibration-proof pad.
                  Special note: in the air compressor exit strong vibration, cannot install the sensors, shall be installed after the gas storage.
                  4, demand for air condition:
                  A, the gas to be tested for single phase pipe flow, continuously flowing through a pipe.
                  Before b, the gas flows through the flowmeter, the flow rate must be parallel to the pipe axis, can not have vortex flow.
                  C, flow should be a subsonic, a pulse, its flow change slowly over time.
                  5, the flowmeter installation requirements:
                  Vortex street flowmeter to process the installation and use of the special requirements of environment is not too much, but any kind of flow measurement instrument has such a common, as far as possible to avoid vibration and high temperature environment as flow interference elements (such as compressor, separator, pressure regulating valve, reducer, and pipe, elbow, etc.), keep straight pipe before and after the instrument inside sleek straight, ensure to clean single-phase fluid measured medium, etc.

                  Need to pay attention to during the period of eight, debugging, using question:
                  1, flowmeter, on-site installation, maintenance, must abide by the "explosion-proof gas do not open" warnings, and in the open before turn off the power supply.
                  2, vortex flow meter used in outdoor, suggestion and side shields.
                  3, shall not be arbitrarily fixed part loosen the flowmeter.The protection of the pressure sensor.Users in the use of traffic time, should pay attention to the flow pressure overload value of pressure sensor is rated working pressure of 1.5 times (that is, the media zui high pressure of 1.5 times).Selection should be within the prescribed flow range, prevent overspeed operation, in order to obtain the ideal accuracy and ensure the normal service life.(due to pressure test, purging pipes or exhaust overdrive, and turbine operation in the reverse flow meter can cause damage)
                  4 when put into operation, the vortex street flowmeter, should slowly open valve, prevent damage of instantaneous flow and the turbine.Add lubricant should be according to the sign, the number of refueling depends on temperament clean degree, usually 2 ~ 3 times a year.
                  5, vortex street flowmeter runtime or alternate internal related parameters are not allowed to open the rear cover, otherwise will affect the normal operation of the meter.
                  Nine, install and use the items that should be paid attention to:
                  Vortex street no mechanical moving parts, small size, corrosion resistance, stable performance, can be directly display medium work pressure, temperature, flow rate and volume under standard state, wide range, the advantages of small measurement error, has been widely used in oil and gas well production measurement and gas sales.In field application over the years, we believe that the meter is suitable for relatively clean dry gas metering, gradually become small and medium-sized gas metering.To guarantee the accuracy of the flowmeter measurement, reduce the measuring error, please note:
                  1, the selection of reasonable
                  Don't make the actual small flow meter QVmin below the selected through runoff flow range limit.
                  2, installation is correct
                  Upstream of the vortex flowmeter should have at least 10 d measuring straight pipe length.Straight pipe inner surface should be smooth, cannot have the steps, more smooth connecting flange weld, flange gasket can't into the pipe.Don't put the wrong installation direction of the flow meter.Tests showed that: all the unreasonable installation, will lead to the flowmeter measurement value is low.
                  3, away from the source of shocks, or install piers in upstream or downstream flow meter, in order to avoid the influence of the pipeline vibration.Avoid strong magnetic field disturbance to the flow meter chip.
                  4, temperament is relatively clean
                  Especially not a gas liquid two phase flow;Temperament is dirty, should clean instant flow meter.
                  5, and reduce the influence of flow pulsation
                  It can be installed in front of the flow meter buffer tank, or extended length of straight pipe upstream of the flow meter, computation.
                  6, timely flowmeter for metrological verification, to ensure accurate and reliable value.

                  Ten, field requirements:
                  1, low maintenance - most of the vortex flowmeter are on the market with induction swirl hole or plug-in measurement, once the impurities embedded in the medium pressure hole or sensing element and the table body, the gap between the signal is weak or unstable.A good design should be not easy to plug part, thereby reducing amount of maintenance.
                  2, inductive components online replacement - some manufacturer of inductive components and vortex street close 2 for one, seemingly simple design to the actual use of inconvenience.Because once induction part failure, you need to medium to the pipe emptying replacement parts, after pressure relief effect production.Perfect design should be separated the two, so can replace the induction part alone, without emptying the media.
                  3, vortex flowmeter is vulnerable to vibration interference, well-designed vortex flowmeter can through hardware and digital signal processing to exclude interference, and the stability of the signal is obtained.
                  4, vortex flow meter before and after the installation of a hassle to very long straight section, some manufacturers can offer within the flowmeter reducing design, greatly reduces the user specifically MenWei vortex flowmeter with the demand of the straight pipe.

                  Eleven, installation requirements:
                  1, the sensor can be installed indoors, can also be installed in the outdoor.Environmental conditions to conform to the requirements.
                  2, sensors should be installed in a horizontal, vertical or inclined (fluid flow from bottom to top) and its corresponding pipe nominal diameter.
                  3, sensors installed on a mechanical vibration of pipeline should be avoided.Should be considered when the vibration is inevitable, at about 2 dn from sensor before and after the straight pipe and fixing racks.
                  4, avoid install the sensor sensing has strong electromagnetic interference, thermal radiation, corrosive gas, the space is little, and maintenance is not convenient.
                  5, when measured medium contains many impurities, at the request of straight pipe upstream from sensors mounted outside the length of the filter.
                  6, either upstream or downstream of the sensor should be configured with a certain length of straight pipe, straight pipe inner surface should be clean, smooth, no obvious convex concave, fouling and peeling phenomenon.Its length should conform to the requirements of figure 2.Installation of the liquid sensor, near the pipe should be filled with liquid to be tested.
                  7, straight pipe diameter as far as possible consistent with the sensor size, if not consistent, slightly larger diameter than the sensor size should be adopted, the error to 3% or less is not more than 5 mm.
                  Twelve, matters needing attention:
                  1, special flange and straight pipe welding can't with the sensor.
                  2, when installation should make the flow of sensor mark the direction of flow and the pipe.
                  3, before the installation of sensor and the flange must be put away in sealing ring grooves.The location of the pressure and temperature measurement point, pressure downstream of the sensor in 3 ~ 5 dn, temperature measuring points in the downstream of 5 ~ 8 dn.
                  4, when measuring high temperature medium, do not use heat insulation material to wrap around the sensor link rod.
                  Five, connection of shielded cable, should as far as possible away from the interference of strong electromagnetic field.Absolutely not allowed with high voltage cable laying, shielded cable to shorten as far as possible, and shall not be volume, in order to reduce stray inductance, zui big length should be not more than 200 meters.
                  6, before installation of sensors, pipeline cleaning must be conducted.Flow after rinse tube impurities, avoid clogging sensor.Measuring liquid pipe must be full of measured liquid, prevent the interference of bubbles.
                  7, measuring gas pipelines to prevent the interference of reservoir fluid.Replace the probe body under the high temperature and high pressure, it must be safe operation, high temperature protection.After cooling step-down replaceable probe at the bottom of the safety conditions.
                  13, installation specification management:
                  Flowmeter standard installation, to use the department in the subsequent management provide strong technical support, put forward the following specific requirements of the construction unit, after years of validation effect is very good.
                  1, with 4 ~ 20 ma output, pulse output.
                  2, GPRS remote transmission device with pulse input, input 4 ~ 20 ma.
                  3, with power supply prevents thunder and lightning protection (4 ~ 20 ma) signal.
                  4, instrument cabinets for: ark with UPS power supply, open and the socket, the GPRS communication devices, intelligent vortex flowmeter converter such as concentrated installation and lock.
                  5, smooth instrument ark need concrete pier base, instrument protection grade for outdoor cabinet, the ark with insulating layer to prevent sun point-blank, ark with water proof function.
                  6, domestic demand has left side table well enough straight pipe, facilitate intelligent vortex flowmeter test, compare and follow-up management.
                  7, vortex flow timing design front end must have at least 10 times of nominal menstruation (dn) 10 straight pipe, the back-end must leave more than 5 dn straight pipe, to ensure accurate measurement.
                  8, shall be installed in accordance with the specifications and after the installation need measuring grounding, grounding resistance should be under 10 Ω.Equipotential connections using multiple strands of copper wires, cables should be greater than or equal to 16 was;Instrument grounding line using multiple strands of copper conductor, cable requirement was greater than or equal to 6.Grounding standard see GB50343-2009 "technical specification for building electronic information system lightning protection.
                  14, selection of points:
                  Correct selection to ensure that the use of vortex flowmeter is better.Should choose what kind of vortex street flowmeter is based on the current body to determine the physical properties and chemical properties of the medium.Make the size of vortex flowmeter, flow range, lining materials, electrode materials and output current, etc.To be the nature of the flow volume and flow measurement requirements.
                  1, precision function
                  Precision grade and function in accordance with the requirements of measurement and choose the instrument using fine grade, cost-effective.Such as for trade settlement, product transfer and energy measurement occasions, should choose high precision grade, such as 1.0, 0.5, or higher level;Used in process control, according to the requirements of control choose not with precision grade;Some just check process flow, without having to do precise control and measurement, can choose lower precision grade, such as 1.5, 2.5, 4.0, and even then you can choose cheap plug-in vortex flowmeter.
                  2, medium can be measured
                  Medium velocity and diameter, full scale measurement generally medium, the full flow of vortex flowmeter can measure medium velocity in 0.5-12 m/s within the scope of selection, range is wide.Choose different instrument specifications (diameter) and process piping, the same shall consider whether measuring flow range within the scope of the flow velocity, namely when the pipeline flow rate is low, can not meet the requirement of the flow meter, or under the velocity measurement accuracy of the quasi cannot guarantee, the need to reduce the size instrument, which carry high tube flow velocity, measurement results are satisfied.
                  3, the selection of vortex flow transmitter
                  In saturated vapor measurement using VA type piezoelectric vortex flow transmitter, due to the vortex flow meter range wide, therefore, in practice, the measurement of saturated steam flow main consideration shall not be less than the lower limit of vortex flowmeters, that is to say, must satisfy the fluid flow rate shall be not less than 5 m/s.According to the size of the YongQiLiang chooses different caliber of vortex flow transmitter, rather than with the existing technology to choose transmitter diameter pipe size.
                  The choice of 4 pressure transmitter, pressure compensation
                  Because of the saturated steam pipe length, pressure fluctuation is bigger, pressure compensation must be used, considering the pressure, temperature and density, the relation between measurement using pressure compensation, because the pipeline saturated steam pressure in the range 0.3 0.7 MPa, pressure transmitter ranges 1 MPa.
                  5, display instrument selection
                  Display instrument intelligent flow display, a voltage compensation, the instantaneous flow and cumulative flow integrating function.

                  15, standard of flow range profile: unit (m3 / h)

                  traffic 

                  The liquid flow range

                  Gas flow range

                  Saturated steam flow range

                  CAL

                  Small flow

                  Heavy traffic

                  Small flow

                  Heavy traffic

                  Small flow

                  Heavy traffic

                  DN25

                  0.9

                  14

                  8.3

                  110

                  13

                  1500

                  DN40

                  2.5

                  35

                  26

                  300

                  25

                  4400

                  DN50

                  3.3

                  55

                  36

                  480

                  40

                  6800

                  DN80

                  8

                  150

                  90

                  1300

                  100

                  19000

                  DN100

                  14

                  240

                  140

                  2000

                  160

                  29000

                  DN150

                  38

                  450

                  290

                  4100

                  350

                  66000

                  DN200

                  70

                  850

                  620

                  7500

                  620

                  118000

                  DN250

                  130

                  1300

                  700

                  12500

                  970

                  185000

                  DN300

                  180

                  2000

                  920

                  16500

                  1400

                  267000

                  16, selection of coding:

                  Code name

                  size

                  Flow range ㎡/h(In the wei and control)

                  ZW-LUGB-25

                  DN25

                  1 ~ 10(liquid)

                  25 ~ 60(gas)

                  Steam flow check specifications,DN300The above recommended plug-in vortex flowmeter

                  ZW-LUGB-32

                  DN32

                  1.5 ~ 18(liquid)

                  15-150(gas)

                  ZW-LUGB-40

                  DN40

                  2.2 ~ 27(liquid)

                  22.6 ~ 150(gas)

                  ZW-LUGB-50

                  DN50

                  4 ~ 55(liquid)

                  35 ~ 350(gas)

                  ZW-LUGB-80

                  DN80

                  9 ~ 135(liquid)

                  90 ~ 900(gas)

                  ZW-LUGB-100

                  DN100

                  14 ~ 200(liquid)

                  140 ~ 1400(gas)

                  ZW-LUGB-150

                  DN150

                  32 ~ 480(liquid)

                  300 ~ 3000(gas)

                  ZW-LUGB-200

                  DN200

                  56-800(liquid)

                  550 ~ 5500(gas)

                  Code name

                  function1

                  N

                  No temperature pressure compensation

                  Y

                  With temperature compensation

                  Code name

                  Output type

                  F1

                  4-20mAOutput (two-wire system)

                  F2

                  4-20mAOutput (three-wire system)

                  F3

                  RS485Communication interface

                  Code name

                  Measured medium

                  J1

                  liquid

                  J2

                  gas

                  J3

                  steam

                  Code name

                  The connection method

                  L1

                  Flange mounted

                  L2

                  Flange connection type

                  Code name

                  function2

                  E1

                  1.0level

                  E2

                  1.5level

                  T1

                  The normal temperature

                  T2

                  The high temperature

                  T3

                  steam

                  P1

                  1.6MPa

                  P2

                  2.5MPa

                  P3

                  4.0MPa

                  W1

                  internal3.6VThe power supply

                  W2

                  DC24VThe power supply

                  N1

                  Stainless steel

                  N2

                  Carbon steel

                  N3

                  Anti-corrosion type

                  17,Order to choose selection guidelines:

                  Name and model number of 1, 1), (2) the diameter, flow range, (3) whether or not to bring the attached so that we can correct selection for you, (4) using pressure, (5) the use of medium temperature.

                  2, if has been selected by design units in the way of vortex street flowmeter types, please press type vortex flowmeter directly order from our sales department.

                  3, when using occasions is very important, or the environment is complex, please try to provide the design drawings and detailed parameters, by wei experts in our audit checks for you.

                  After-sales service commitment:

                  1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

                  2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

                  3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

                  4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.

                  Browse:
                  Return To The Top

                  分(fen)亯(xiang)到(dao):

                  Kwboa
                            1. <center></center>