                  Type Selection Instructions for Explosion-proof Metal Tube Rotor Flowmeter
                  • File Name:Type Selection Instructions for Explosion-proof Metal Tube Rotor Flowmeter
                  • Add Time:2019-04-12 10:30:15
                  • Document Size:
                  • Recommendation:
                  • Immediately Download:
                  Download Instructions:

                  Productoverview:
                  ZW-LZ series explosion-proof metal tube rotameter using magnetic sensor, magnetic field change detection angle without contact with the international advanced MCU micro processing system, can realize the liquid crystal indicator, and cumulative output distance (4 20mA), HART protocol, the output pulse output, alarm output function, the intelligent signal transmitter with high precision and reliability, and can completely replace the imported same type instrument.According to the process requirements of the vertical installation under the upper and upper lower side into the side and the bottom side, threaded connections, clamp connections, horizontal installation installation optional.
                  Second, the structure and principle of measurement:
                  ZW-LZ series explosion-proof metal tube rotameter consists of two parts:
                  The sensor - measuring tube and float;
                  Signal transmitter - indicator;
                  Touch sensor with liquid material: stainless steel, Hastelloy, titanium, stainless steel PTFE; users in the selection, you can choose different combination of indicator, to achieve different measurement requirements, see type indicator system.
                  Flow measurement is changed by the transmitter indicator in the magnetic coupling force to complete the feelings float.When the measured medium flows through the measuring tube, float by gravity, buoyancy and flow velocity of the float force to achieve dynamic balance, which is relatively static in a position ring area, fluid velocity changes in the position with the float and cone tube, the float position corresponds to the corresponding flow.
                  Third, widely used:
                  ZW-LZ series explosion-proof metal tube rotameter applicable to all industries complex, harsh environment, flow measurement and process control of small flow, low flow rate, a variety of harsh medium conditions.Widely used in petroleum, chemical, power, pharmaceutical, food, water treatment, etc..The complex, harsh environmental conditions, the flow measurement process and various medium conditions in.
                  Fourth, the main features:
                  Convenient 1, modular design, maintenance, maintenance of normal use;
                  2, intelligent with power-off protection, data backup and recovery function;
                  3, single axis, non-contact magnetic coupling structure model, the signal transmission is more stable;
                  4, all metal structure, seismic, pressure resistance, temperature resistance, corrosion;
                  5, double row, large screen liquid crystal display instantaneous and cumulative flow, with backlight;
                  6, HART communication protocol.
                  Five, technical parameters:
                  Measuring range: water (20 C) 6~200000 l/h; air (0.1MPa 20 C) 0.03 ~ 4000 m3/h;
                  Range: 10:1;
                  The accuracy level: 1.5 (out of 1);
                  Working pressure: DN15 ~ DN50 PN4.0MPa (special 32MPa);
                  DN80 ~ DN200 PN1.6MPa (special 25MPa);
                  The medium temperature of - 40 DEG C to +120 DEG C (the electric remote type is less than or equal to 85 DEG C);
                  Medium viscosity: DN15 = 5mPa.s (H15.0 ~ H15.4);
                  30mPa.s (H15.5 ~ H15.9);
                  DN25: = 250mPa.s;
                  DN50 ~ DN150: = 300mPa.s;
                  Liquid crystal display: instantaneous flow rate: 0~50000;
                  Cumulative flow rate: 0 ~ 99999999;
                  Output: standard two-wire signal: 4 ~ 20mA;
                  Pulse signal: minimum interval 50ms;
                  Alarm: alarm relay contact capacity, 1A-30VDC;
                  0.5A-125VDC or 0.25A-250VAC;
                  Power supply: Standard Type: 24VDC (10.8VDC ~ 36VDC);
                  AC: 220VAC (85VAC ~ 265VAC);
                  Battery type: 3.6-5.2AH lithium battery;
                  Connection: thread connection type: DIN11851 or the user specified;
                  Electrical connection: M20 * 1.5, PG11, 1/2 NPT;
                  Overall height: Standard Type: 250mm (vertical);
                  Protection grade: IP65;
                  Explosion proof mark: intrinsically safe: ExiaIICT3 ~ 6; flameproof type: ExdIIBT4 ~ 6.

                  Six, the instrument installation requirements.
                  Remove the filler, 1 meter box after check, the meter should be installed vertically in the pipeline without vibration, such as to the level of the installation, the order should be additional instructions.The angle between the line and the plumb line flowmeter center should not exceed 5 degrees.
                  In 2, the newly installed pipeline flow meter should be installed before the new pipeline clean metal pipe, if the measured medium containing impurity particles or bubbles, you should install filtering device or exhaust in flowmeter installation, the fluid must be flowing from down to up, if the fluid flow from top to bottom, then the flowmeter can not work.If the measured medium is pulsating flow, it should be appropriate to the size of the buffer device is arranged in the downstream, such as surge tank to eliminate pulsation.
                  3, in order to check the meter zero and disassembly and maintenance and debugging, should stop valve and bypass valve installed in the upstream and downstream flow meter.
                  4, an instrument according to the provisions after installation, should close the flow meter on the downstream shut-off valve, check again with the two meter instrument wiring, error free, open the two meter power supply is the instantaneous flow rate should be zero.For normal use, you should first open the upstream valve is fully open, with a metal tube rotameter downstream valve from slowly adjust the flow, instantaneous flow should change.Stop working when they should close the valve, then close the upstream downstream of the valve.
                  Seven, product maintenance:
                  1, in the process of long-term use, the pipeline inevitably there will be ferromagnetic impurity adsorption on the float, it will float stuck or affect the measurement accuracy, from time to time to clean the sensor float; if the installation of magnetic filters should be cleaned regularly.
                  2, instrument indicator equipped with electronic components, instrument wiring or demolition of housing, to housing screws, must ensure sealing, prevent impurities, or other material into the water, and also to ensure reliable earthing of the meter casing.
                  3, instrument installation, on first use, should pay attention to:
                  When the valve is opened to avoid the formation of pressure shock makes the float slamming limiting device, causing damage to the instrument, slowly open the valve!
                  The measurement of gas meter is equipped with gas damper, to minimize the shock; to ensure the stability of the float, a throttle valve can be installed in the instrument export.
                  4, for the remote type instrument, we must first ensure that the instrument wiring correctly, keeps power; for dangerous situations, must choose the explosion-proof, and the installation and use of proof required by the.
                  Eight, installation notes:
                  In order to keep the normal work of the flow meter and can reach a certain accuracy, in the installation of the flow meter should pay attention to the following points:
                  1, must be installed vertically in the pipeline without vibration.The fluid flowing through the flow meter and the verticality of bottom-up, less than 2 degree, the level of the installation of horizontal angle less than 2 degree;
                  2, in order to facilitate the maintenance and replacement of flowmeter, measuring pipeline cleaning, rotameter installed in the pipeline should be installed on the bypass pipe and bypass valve;
                  Straight section 3, the entrance should be 5 times the diameter of the length of straight pipe should be 250mm, export;
                  4, if the medium containing magnetic material, magnetic filter should be installed; if containing solid impurities in the medium, should consider adding a filter between valve and pipe;
                  5, when used to measure the gas, should ensure that the pressure loss of pipeline pressure not less than 5 times of the flowmeter, in order to make the float stability;
                  6, in order to avoid the deformation caused by the flowmeter due to pipe, flange and flange coaxial process pipeline must flow and parallel to each other, to support the pipeline to avoid vibration and reduce flowmeter axial load, control valve in the measurement system should be installed in the downstream of the flowmeter:
                  7, measurement of gas, if the gas is directly discharged to the atmosphere in the meter is to be installed in the valve outlet, instrument export, otherwise it will float in the generated pressure drop caused by the distortion of the data.
                  8, install the PTFE lining instrument, flange nuts do not arbitrarily asymmetric overdone, so as not to cause PTEF lining deformation;
                  9, with a liquid crystal display instrument, to avoid direct sunlight, so as not to reduce the service life of the liquid crystal; with lithium battery powered instruments, to avoid direct sunlight and high temperature environment (65 = C) so as not to reduce the capacity and lifetime of lithium battery.
                  9 and fault elimination method:
                  Set alarm 1, check the SU in size.
                  2, check the deviation set D value can not be too large.
                  3, FUN function, logic function is correct.HA-A said the upper limit is logical.LA-A said the lower limit is.
                  4, circuit board failure, replace the board.
                  5, if the lcd barcode indicates the correct output, no action, the cathode can check the external power and external power supply is connected with the anode of instrument power supply.
                  If the metal tube rotameter jitter in use, according to the jitter amplitude to determine what kind of amplitude jitter.Divided into mild and moderate jitter jitter jitter and jitter.
                  1, a slight jitter due to fluctuations caused by the media.Can be used to increase the damping of the way to overcome.
                  2, moderate jitter caused by medium flow state: general.For general gas as the medium pressure instability caused by.The regulator or stabilizer to overcome or increase the damping of gas meter.
                  3, severe jitter: mainly due to medium gas pulsation, operation pressure instability or give users pressure, temperature, flow meter and the actual state does not have large differences over range instrument.

                  Table ten parameters:

                  Path

                  (mm)

                  Flow range

                  The pressure loss of KPa

                  Water L/h

                  Air m3/h

                  water

                  atmosphere

                  The conventional type

                  Anti-corrosion type

                  The conventional type / anti-corrosion type

                  The conventional type

                  Anti-corrosion type

                  Fifteen

                  2.5-25
                  4.0-40
                  6.3-63
                  10-100
                  16-160
                  25-250
                  40-400
                  63-630

                  2.5-25
                  4.0-40
                  6.3-63
                  10-100
                  16-160
                  25-250
                  40-400

                  0.07-0.7
                  0.11-1.1
                  0.18-1.8
                  0.28-2.8
                  0.48-4.8
                  0.7-7.0
                  1.0-10.0
                  1.6-16.0

                  Six point five
                  Six point five
                  Six point six
                  Six point six
                  Six point eight
                  Seven
                  Eight point six
                  Eleven point one

                  Five point five
                  Five point five
                  Five point six
                  Five point six
                  Five point eight
                  Six point one
                  Seven point three

                  Seven point one
                  Seven point two
                  Seven point three
                  Seven point five
                  Eight
                  Ten point eight
                  Ten
                  Fourteen

                  Twenty-five

                  100-1000
                  160-1600
                  250-2500
                  400-4000

                  63-630
                  100-1000
                  160-1600
                  250-2500

                  3-30
                  4.5-45
                  7-70
                  11-110

                  Seven
                  Eight
                  Ten point eight
                  Fifteen point eight

                  Five point nine
                  Six
                  Six point eight
                  Nine point two

                  Seven point seven
                  Eight point eight
                  Twelve
                  Nineteen

                  Fifty

                  630-6300
                  1000-10000
                  1600-16000

                  400-4000
                  630-6300
                  000-10000

                  18-180
                  25-250
                  40-400

                  Eight point one
                  Eleven
                  Seventeen

                  Six point eight
                  Nine point four
                  Fourteen point five

                  Eight point six
                  Ten point four
                  Fifteen point five

                  Eighty

                  2500-25000
                  4000-40000

                  1600-16000
                  2500-25000

                  60-600
                  80-800

                  Eight point one
                  Nine point five

                  Six point nine
                  Eight

                  Twelve point nine
                  Eighteen point five

                  One hundred

                  6300-63000

                  4000-40000

                  100-1000

                  Fifteen

                  Eight point five

                  Nineteen point two

                  One hundred and fifty

                  20000-100000


                  600-3000

                  Nineteen point two


                  Twenty point three

                  Eleven, selection table:

                  Specification code

                  Explain

                  The name of the factory

                  ZW

                  Zhongwei control

                  Instrument types

                  LZ

                  Metal tube rotameter

                  structural style

                  A

                  In the next

                  B

                  Progress under the

                  C

                  Side measure

                  D

                  The bottom side

                  R

                  Right into the left out

                  L

                  The left into the right

                  K

                  Clamp connection (sanitary polishing tube)

                  W

                  Threaded connection

                  Size code

                  - XXX

                  DN15 said: 15 cases

                  The measuring tube material

                  R1

                  1Cr18Ni9Ti, 304

                  R0

                  0cr18Ni12M02Ti, 316

                  RL

                  316L

                  RP

                  PTFE (PTFE)

                  Ni

                  Hastelloy (Hastelloy C)

                  Ti

                  TitHXium (Tai Hejin)

                  Media type

                  L

                  liquid

                  G

                  Gas

                  working temperature

                  H1

                  - 40 -100 OC

                  H2

                  - 80 -250 OC

                  Rated pressure

                  One point six

                  1.6MPa

                  Four

                  4.0MPa

                  Sixteen

                  16MPa

                  Twenty-five

                  25MPa

                  Additional structure

                  O

                  nothing

                  Z

                  Damping type

                  T

                  Jacket

                  H

                  High temperature type

                  Y

                  High pressure type

                  Form indicator

                  M1

                  Local indication

                  M2

                  Intelligent

                  M3

                  Intelligent (explosion)

                  The output signal in the communication

                  N

                  nothing

                  A

                  4-20mA

                  H

                  4-20mA+Hart

                  Alarm controller

                  K1

                  The upper limit alarm

                  K2

                  Alarm

                  K12

                  The upper and lower limit alarm

                  Explosion proof type

                  E1

                  Intrinsically safe EXiaCT5 square casing

                  E2

                  Flameproof shell EXiibt4 Park

                  Power supply

                  Zero

                  24VDC (optional)

                  Two

                  220VAC

                  Three

                  The 3.6 volt lithium battery