                  High negative pressure transmitter

                  M3051高精度正負壓力變送器.jpg
                  • M3051高精度正負壓力變送器.jpg
                  ZW3051SP seriesHigh negative pressure transmitterThe overseas advanced production technology and equ…

                  Description:

                  ZW3051SP seriesHigh negative pressure transmitterThe overseas advanced production technology and equipment of new type of transducer, the key raw materials, components and parts are imported, the whole machine after assembled and tested strictly, this product has the advanced design principle, the variety specification is complete, installation convenient use, etc.Due to the aircraft appearance on the total integration of the current domestic zui is popular, strong commonality and replace ability.For the continuous improvement of the domestic automation level and the development, this series of products in addition to the design cabinet and delicate, more has introduced HART field bus protocol of intelligent function.

                  Second, the working principle:

                  ZW3051SP series high precision negative pressure transmitter is when two of the measured medium pressure ventilation with high and low pressure chamber, two role in the delta components (i.e., sensitive element) on either side of the segregation on the diaphragm, through spacer and components on both sides of the filling liquid to measure the diaphragm.Measuring diaphragm and on both sides of the insulation on the electrodes of a capacitor.When we have different pressure on both sides, to cause measuring diaphragm displacement, the displacement and stress is directly proportional to the difference, so both sides capacitance range, through the link of oscillation and demodulation, is converted into is proportional to the pressure signal.

                  Applications:

                  ZW3051SP series negative pressure transmitter is mainly used for high precision measurement of gas, liquid and steam parameters such as pressure, absolute pressure and negative pressure, and then convert them into 4-20 ma. DC signal output.High precision pressure transmitter it can accord with the hand of the HART protocol operator mutual communication, it can measure the exhaust system, distillation tower, evaporator pressure and mould.

                  Four, the main features:

                  1, high precision;

                  2, good stability;

                  3, 4-20 madc two wire;

                  4, solid element, plug type printing circuit board;

                  5, small, light weight, strong earthquake;

                  6, continuous tunable range, zero external;

                  7, positive transfer of 500%;Negative transfer of 600%;

                  8, damping adjustable;

                  9, one-way overload protection characteristics;

                  10, no mechanical moving parts maintenance work less;

                  11, the structure of the whole series of unified, strong parts interchangeability;

                  12, optional contact medium diaphragm material (316 l, TAN, HAAS - C, MONEL and other corrosion resistant material);

                  13, explosion-proof structure, all-weather use;

                  14, intelligent HART fieldbus protocol.

                  Five, the performance parameters:

                  1, use object: liquid, gas and steam;

                  2, measuring range: 0-0.06 kPa to 0 to 40 mpa;

                  3, the output signal: 4-20 ma DC;

                  4, 12-45 VDC, general is 24 VDC;

                  5, load characteristic: related to the power supply, load ability in the era of a power supply voltage (load), RL load impedance and voltage VS relation is: RL (v - 12) or less;

                  6, indicator: LCD or LFD digital tube display.

                  7, explosion proof: flameproof dIIBT4 b: intrinsically safe iaIICT6;

                  8, range and zero: external continuous adjustable;

                  9, plus or minus migration: zero after positive transfer and negative transfer, range, measurement range, of the absolute value of the upper limit and lower limit are less than 100% of the measurement range limit (intelligent: range than 15:1) the most-positive migration amount 500% of the smallest calibration range;The largest amount of negative transfer of 600% of the minimum working range;

                  Working temperature range, temperature range: 10 amplifier: - 29 ~ + 93 ℃ (LT is 25 ~ + 70 ℃) pump silicone oil measuring element: - 40 ~ + 104 ℃ when the pump flange transmitter high temperature silicone oil: + 15 ~ + 315 ℃, normal silicone oil: - 40 ~ + 149 ℃;

                  11, the static pressure: 1, 4, 10, 25, 32 mpa;

                  12, the temperature, relative humidity of 0 ~ 100% RH.

                  13, volume variation: < 0.16 cm3;

                  14, damping (step response) : silicone oil filling, generally between 0.2 s to 1.67 s continuous adjustable.

                  Six, the technical parameters:

                  (without migration, in standard working conditions, silicone oil, 316 stainless steel isolation diaphragm);

                  1, accuracy: + / - 0.075% (0 intelligent), plus or minus 0.1% (smart), plus or minus 0.25%, plus or minus 0.5%;

                  2, dead zone: no (0.1%) or less;

                  No more than 3, stability: six months the basic error of the absolute value of maximum range;

                  4, vibration impact: on any axis, the vibration frequency of 200 hz;

                  5, power supply: less than 0.005% of output range V.

                  6, the load effects: power if stability, the load has no effect;

                  7, installation location: the biggest can produce 0.24 kPa zero error.

                  Other:

                  1, isolating diaphragm: 316 stainless steel, hartz alloy C - 276, monel alloy, titanium or tantalum;

                  2, vent/drain valve: 316 stainless steel;

                  3, flange and fittings: 316 stainless steel;

                  4, contact medium "O" ring: nitrile rubber, fluorine rubber;

                  5, pouring liquid: silicone oil or inert;

                  6, bolt: 316 l stainless steel;

                  7, electronic shell material: low copper aluminum alloy;

                  8 and pressure fittings: flange 1/4 NPT, center distance of 54 mm;1 1/2 NPT or M20x1 joint. 5 male thread taper sealing ball, belt joint center distance, 54, 57.2 50.8 mm;

                  9, signal wiring hole: G1/2.

                  Seven, fault diagnosis:

                  Transducer in the measurement process, often appear some fault, fault of decision analysis and handling in time, is very important for ongoing production.We according to the experiences of the daily maintenance and some decision analysis method and the analysis process were summarized.

                  1, the investigation method:

                  Review before failure of flint, smoke, odor, power supply change, lightning, damp, wrong operation, and maintenance.

                  2, intuitive method:

                  Observation circuit of external injury, guide of pressure pipe leaking, overheating in the circuit and power supply switch state, etc.

                  3, test.

                  A, open circuit detection: separately from the rest parts of the suspected fault and to see whether the fault disappear, if lost, then determine the malfunction, or can be carried out to find the next, such as: smart differential pressure transmitter can't normal Hart, telecommunication, power supply can be disconnected from the instrument noumenon, the method of field plus a power transmitter power to communicate, to see if the cable stack 2 KHZ electromagnetic signals interfere with communication.

                  B, short circuit test: in the case of security, the related part of the loop short directly, such as: small difference transmitter output value, can guide tube disconnected, from a valve directly to the outside differential pressure signal directly led to the differential pressure transmitter, on both sides to observe the transmitter output, to determine the pipeline wall, leakage of connectivity.

                  C, replace, test: will doubt defective parts replacement, judge fault position.Such as: suspected transmitter circuit board failure, can be temporary replacement, to determine the reason.

                  D, division of detection: the measuring circuit of divided into several parts, such as: power supply, signal output, signal transmitting, signal detection, according to the points of inspection, by Jane to numerous, situated in, narrow range, find out the fault location.

                  Eight, installation requirements:

                  1, before installation, please read carefully the product specification, and check the related information of the product.

                  2, the transmitter shall be installed in ventilated, dry, no corrosion, shady and cool place, such as outdoor installation should add protective cover, avoid sun and rain, avoid transmitter performance degradation or failure.

                  3, the transmitter is a precision instrument, avoid strong shocks, throw during installation.

                  4, according to the wiring diagram properly connected.

                  5, pay attention to protect transmitter which leads to the cable.When used in industry site, it is recommended to use metal protection or overhead.Do not loose cable leads to the sealing nut, to avoid moisture to enter.

                  Nine, use notice:

                  Pressure sensor points in the process of using, transmitter in the correct installation position on process piping and the measured medium, to effect have to the measurement result, should pay attention to consider the following situations:

                  1, guide pressure pipe shall be installed where the temperature fluctuations small;

                  2, measuring, liquid pressure transmitter installation location should avoid the impact of the fluid (water hammer), in order to avoid the sensor damage of overpressure.

                  3, prevent the dross in intraductal deposition;

                  4, measuring the liquid pressure, pressure pipe side should be open in the process, in order to avoid precipitation product residue.

                  5 and freezing in winter, when installed in the outdoor anti-freezing measures needed for transmitter, without pressure, fluid due to the icing volume expansion in the mouth, lead to the damage of sensors.

                  6, to prevent the transmitter contact with corrosive or overheating of medium;

                  7, connection, cable through the waterproof connector (attachment) or round tube and screw down the sealing nut, such as in case of rain through the cable leakage into the transmitter inside the shell.

                  8, measuring, steam or other high temperature medium to connect with the buffer tube (coil) such as condenser, should not make the transmitter operating temperature more than limit.

                  9, measuring gas pressure, the pressure mouth should be open at the top of the process piping, and the upper transmitter should be installed in the process, so that the accumulated liquid injection process pipeline easily.

                  Ten, selection of code:

                  Code name

                  The name According to

                  ZW3051SP

                  In the negative pressure transmitter (wei measurement and control)


                  Code name

                  instructions


                  0

                  Negative pressure


                  1

                  Gage pressure


                  2

                  Absolute pressure


                  Code name

                  Measuring range


                  1

                  0-0.06~0.3KPa


                  2

                  0-0.25~1.5KPa


                  3

                  0-1.2~7.2KPa


                  4

                  0 to 6~36KPa


                  5

                  0 to 30~180KPa


                  6

                  0-160.~1000KPa


                  7

                  0-400.~2500KPa


                  8

                  0-1600.~10000KPa


                  9

                  0-4000.~25000KPa


                  0

                  0-7000.~40000KPa


                  Code name

                  type1


                  0

                  standard


                  1

                  Single flange type


                  2

                  Double flat flange type


                  3

                  Single flange type


                  4

                  Double flange type


                  5

                  A single flange type


                  Code name

                  Flange specifications


                  0

                  DN25


                  1

                  DN50


                  2

                  DN80


                  3

                  Other specifications


                  Code name

                  type2


                  0

                  ordinary


                  1

                  General intelligent(HARTcommunication)

                  generation No.

                  containing The righteous

                  MO

                  Don't take show

                  M1

                  Digital indication header

                  E1

                  Ordinary cable joint

                  E2

                  The explosion-proof cable joint

                  B1

                  Bend tubes of stents

                  B2

                  Plate bracket with bending

                  B3

                  Pipe bracket with flat

                  G1

                  Waist flange type

                  G2

                  Welded pipe joint

                  G3

                  The integration of three valve group

                  i

                  The Ann

                  d

                  flame-proof

                  G

                  200 or less℃ (high temperature silicone oil)

                  mark quasi type

                  Anti-corrosion materials

                  Structural materials

                  Isolation diaphragm

                  F12

                  316L

                  F13

                  hartzC-276

                  F14

                  monelK-500

                  F15

                  tantalum

                  F22

                  316L

                  F23

                  hartzC-276

                  F24

                  monelK-500

                  F25

                  tantalum

                  F26

                  316L

                  F33

                  hartzC-276

                  F35

                  tantalum

                  F44

                  monelK-500

                  F47

                  3YC25

                  Eleven, design selection and ordering information:

                  1, ZW3051SP series negative pressure transmitter type according to the selection of specification table according to the need to make sure.

                  2, selection of specifications in the table Numbers, symbols must be fill in clear, accurate.

                  3, if you have positive and negative migration, must indicate the migration amount value.

                  4, differential pressure transmitter to match three valve group, the throttle device, need to be indicated separately.

                  5, according to the user specified range checking.If the user has no rules, set at maximum range in the transmitter, the check will be carried out under room temperature and atmospheric pressure.

                  6, need labeling station number, should be indicated when ordering.

                  7, when far eastone transmitter of choose and buy, should also be based on different remote flange selection table according to the need to be sure.

                  8, if remote transmitter should be used in vacuum and high temperature occasion, special label when you order.

                  9, contact medium type O sealing ring material with nitrile butadiene rubber, fluorine rubber, etc.

                  After-sales service commitment:

                  1, our company sold by wei pressure transmitter series products appear quality problem, within twelve months for free maintenance.

                  2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.

                  3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.

                  4, after the warranty period appear quality problem, my company is responsible for the maintenance, charge damage parts cost.

                  5, such as user need to my company site services, to users in the province I company service personnel to reach the site within 12 hours, fujian association of foreign languages and user reach the site within 48 hours.