1. <center></center>

                1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
                  0517-86918678
                  Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
                  Tel:0517-86918678
                  Fax:0517-86918679
                  Email:zhongweick@https://zghzyb.com
                  Post Encoding:211600

                  Explosion-proof differential pressure transmitter

                  A3351防爆(bao)差壓變送(song)器(qi)01.jpg
                  • A3351防爆(bao)差壓變送器(qi)01.jpg
                  The application of digital technology in ZW3351DP series explosion-proof differential pressure trans…

                  Description:

                  I. Product Overview:

                  The application of digital technology in ZW3351DP series explosion-proof differential pressure transmitter not only ensures the high reliability and other superior performance of the instrument, but also realizes the real-time self-checking configuration operation of the intelligent instrument and the remote digital connection between the control room and the control room, and realizes the remote inquiry or real-time configuration of the unit instrument in the control room. High accuracy and good stability. Range, zero external adjustable. Miniaturization, light weight, strong vibration resistance. No mechanical moving parts, reliable operation, easy maintenance. Solid element, plug-in printed circuit board. Explosion-proof structure, can be used all day.

                  II. Working Principle:

                  ZW3351DP series explosion-proof differential pressure transmitter measures two kinds of pressure of medium into high and low pressure chamber, which acts on the isolation diaphragm on both sides of the delta element (i.e. sensitive element), and is transmitted to both sides of the measuring diaphragm through the isolator and filling liquid in the element. A capacitor is formed by measuring the diaphragm and the electrodes on both sides of the insulating sheet. When the pressure on both sides is inconsistent, the displacement of the diaphragm is proportional to the pressure difference, so the capacitance on both sides is different, and the signal is converted into a signal proportional to the pressure through oscillation and demodulation.

                  3. Application occasions:

                  ZW3351DP series explosion-proof differential pressure transmitter is used to measure liquid level, flow rate and pressure of liquid, gas or steam under high working pressure environment, and then convert it into 4-20mA DC signal output. Intelligent type can communicate with HART hand-operated device, through which setting, monitoring or composing on-site monitoring system with upper computer.

                  Fourth, main characteristics:

                  1. Super measurement performance for pressure, differential pressure, liquid level and flow measurement;

                  2. Digital accuracy: +(-) 0.05%;

                  3. Stability: 0.25% for 60 months;

                  4. Range ratio: 100:1;

                  5. Measurement rate: 0.2S;

                  6. Miniaturized (2.4kg) stainless steel flange, easy to install;

                  7. Process connection is compatible with other products to realize measurement.

                  8. The sensor (technology) with H-alloy sheath has achieved excellent cold and thermal stability.

                  9. Differential pressure transmitter with 16-bit computer;

                  10. Standard 4-20 mA with digital signal based on HART protocol.

                  Technical parameters:

                  1. Targets: liquids, gases and vapors;

                  2. Measurement range: 0-1.6-10 MPa;

                  3. Output signal: 4-20mA DC (special for four-wire system); 220V AC power supply, 0-10mA DC output;

                  4. Power supply: 12-45V DC, generally 24V DC;

                  5. Load characteristics: related to power supply, with load capacity at a certain power supply voltage; the relationship between load impedance RL and power supply voltage Vs is: RL < 50 (Vs-12);

                  6. Indicator table: pointer linear indicator 0-100% calibration and LCD liquid crystal display;

                  7. Explosion-proof grade: a: Exd II BT5 or Exd II CT6; b: intrinsically safe type (Exia II CT6 or Ex IB II CT6);

                  8. Range and Zero: External continuous adjustable.


                  Browse:
                  Return To The Top

                  分亯到:

                  oNnNF
                            1. <center></center>