                  Universal type double metal thermometer

                  5萬(wan)曏型(xing)雙(shuang)金屬(shu)溫度(du)計(ji).PNG
                  • 5萬曏(xiang)型雙金(jin)屬溫度計(ji).PNG
                  WSS series Universal type double metal thermometer Compared with the domestic similar products: inst…

                  Description:

                  Productoverview:
                  WSS series Universal type double metal thermometer Compared with the domestic similar products: instrument precision grade 1.0, instrument shell made of anti-corrosion materials, its temperature can be as high as 200 c, Zui low -40 C. Flange type structure, double sealing ring, the anticorrosion, good waterproof performance. The protective tube welded by automatic argon protection tube, solid weld, small intergranular corrosion. The dial is aluminum oxide printing plate, clear surface styling. For the adjustable pointer.
                  Two, work principle:
                  WSS series Universal type double metal thermometer Is the principle of expansion work in varying degrees of temperature change when using two different metals. Industrial use of double metal thermometer main element is one with two or more metal sheet laminated together to form a multilayer metal sheet. In order to improve the measurement sensitivity, usually made of sheet metals of spiral shape. When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen. Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to. The measuring range of this instrument is about 200~650 DEG C, allowable error are 1% of range scale. The use of glass liquid thermometer thermometer and a rod is similar, but can be used in mechanical strength under the condition of higher requirements.
                  Three, application:
                  WSS series Universal type double metal thermometer It can directly measure the production process in a variety of -80 to +500 DEG C range of liquid, steam and gas temperature. Widely used in petroleum, chemical, machinery, shipbuilding, power, textile, printing and dyeing industry and scientific research departments.
                  Four, main features:
                  1, the scene display temperature, convenient safe and reliable, long service life;
                  2, a variety of forms, can meet different requirements. Victims of mercury free, easy reading, strong shock.
                  3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
                  4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
                  5, integrated with axial type, radial type, 135 type, universal type, complete varieties, suitable for various on-site installation need.
                  Five, technical parameters:
                  1, the implementation of standards: JB/T8803-1998 GB3836-83;
                  2, dial diameter: 60100150;
                  3, accuracy: (1, 1.5);
                  4, thermal response time: less than 40S;
                  5, protection grade: IP65;
                  6, adjust the angle error: adjustment angle error should not exceed the range of 1%;
                  7, return difference: double metal thermometer to the difference should be less than the absolute value of the basic error limit;
                  8, repeat: double metal thermometer repeatability limit should be less than the absolute value of basic error of 1/2.

                  Six, Matters needing attention:
                  1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation.
                  2, installation, non twist instrument shell.
                  3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature.
                  4, the instrument can often work in the temperature scale range 1/2 ~ 3/4.
                  5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement.
                  6, do not use media exposure in measuring container.
                  7, the use of the process should pay attention to check in time, probably in about 6 months.

                  Seven, temperature range:

                  The measuring range of C

                  Applicable scope

                  Industrial and commercial

                  Laboratory and small

                  -80 ~ +40

                  B.

                  B.

                  -40 ~ +80

                  B.

                  B.

                  0~50

                  B.

                  B.

                  0 ~ 100

                  B.

                  B.

                  0 ~ 150

                  B.

                  B.

                  0~200

                  B.

                  B.

                  0~300

                  B.

                  B.

                  0~400

                  B.

                  B.

                  0~500

                  B.

                  B.

                  Remarks:
                  One The insertion depth of the thermometer, L Must be greater than Lmin , L Alternative series: One hundred , One hundred and fifty , Two hundred , Two hundred and fifty , Three hundred , Four hundred , Five hundred , Seven hundred and fifty , One thousand , One thousand two hundred and fifty , One thousand and five hundred , Two thousand So, also can be customized according to user needs.
                  Two And the protective tube diameter Phi 6 , Phi 8 The series of thermometers, the time constant is less than FortySecond, diameter Phi 10 When the time constant is less than Thirty Seconds.
                  Three Protect the stainless steel tube 1Cr18Ni9Ti Manufacturing, at room temperature under high working pressure is Zui 6.4MPa .

                  Eight, shape and size:

                  structural style

                  A

                  B

                  C

                  E

                  L

                  D

                  The axial type double metal thermometer

                  Sixty-five

                  Twenty-three

                  Seventy-three

                  -

                  Seventy-five
                  One hundred
                  One hundred and fifty
                  Two hundred
                  Three hundred
                  Four hundred
                  Five hundred
                  Seven hundred and fifty
                  One thousand

                  Phi 6
                  Phi 8
                  Phi 10

                  One hundred and five

                  Twenty-three

                  Seventy-three

                  -

                  One hundred and fifty-five

                  Twenty-three

                  Seventy-three

                  -

                  The radial type double metal thermometer

                  Sixty-five

                  Fifty

                  One hundred and ten

                  Thirty-four

                  One hundred and five

                  Fifty

                  One hundred and ten

                  Thirty-four

                  One hundred and five

                  Fifty

                  One hundred and ten

                  Thirty-four

                  135 degrees to type double metal thermometer

                  One hundred and five

                  Twenty-three

                  Eighty-five

                  -

                  One hundred and fifty-five

                  Twenty-three

                  Eighty-five

                  -


                  One hundred and five

                  Twenty-three

                  One hundred and seventy-eight

                  One hundred and twenty

                  One hundred and fifty-five

                  Twenty-three

                  One hundred and seventy-eight

                  One hundred and twenty

                  Nine, the specific model name that said:

                  Model

                  Measuring range

                  Precision grade

                  Protection tube material

                  Specifications

                  Fixed form

                  D

                  L

                  WSS-480

                  -80 ~ +40
                  -40 ~ +80
                  0 ~ 50
                  0 ~ 100
                  0 ~ 150
                  0 ~ 200
                  0 ~ 300
                  0~400
                  0~500

                  One point five

                  1Cr18Ni9Ti
                  Three hundred and four
                  Three hundred and sixteen
                  316L
                  Hastelloy C-276

                  Phi 100

                  Seventy-five
                  One hundred
                  One hundred and fifty
                  Two hundred
                  Three hundred
                  Four hundred
                  Five hundred
                  Seven hundred and fifty
                  One thousand

                  No fixed device

                  WSS-580

                  Phi 150

                  WSS-481

                  Phi 100

                  Movable external thread

                  WSS-581

                  Phi 150

                  WSS-482

                  Phi 100

                  The movable internal thread

                  WSS-582

                  Phi 150

                  WSS-483

                  Phi 100

                  Fixed thread

                  WSS-583

                  Phi 150

                  WSS-484

                  Phi 100

                  Fixed flange

                  WSS-584

                  Phi 150

                  WSS-485

                  Phi 100

                  Card set screw

                  WSS-585

                  Phi 150

                  WSS-486

                  Phi 100

                  Sleeve flange

                  WSS-586

                  Phi 150

                  Ten, the selection of encoding:

                  Serial number

                  WSS


                  Double metal thermometer (Zhongwei control)

                  Dial diameter

                  -3


                  Phi 60

                  -4


                  Phi 100

                  -5


                  Phi 150

                  Dial form

                  Zero


                  The axial (straight)

                  One


                  Radial (angle)

                  Two


                  135 degrees to (an obtuse type)

                  Eight


                  Universal (angle adjustable type)

                  Fixed form

                  Zero


                  No fixed device

                  One


                  Movable external thread

                  Two


                  The movable internal thread

                  Three


                  Fixed thread

                  Four


                  Fixed flange

                  Five


                  Card set screw

                  Six


                  Sleeve flange

                  Type of protection

                  -


                  Ordinary type

                  W


                  Type of protection

                  F


                  Anti-corrosion type

                  The selection of examples:
                  100, dial diameter, temperature range of 0~400 DEG C, level 1.5, rotatablemale thread M27 * 2 450mm, length WSS-481, 0~400 C, L=450, M27 * 2, 1.5.

                  Eleven, ordering:
                  Please provide the type, dial diameter, precision grade, fixed form, the range of temperature measurement, protection material, pipe length or depth of insertion.
                  Customer service service commitment:
                  1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
                  2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
                  3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
                  4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
                  5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, 48 hours outside users arrive at the scene.


                  Browse:
                  Return To The Top

                  分(fen)亯(xiang)到:

                  qkCoL
                            1. <center></center>