                  Thermal sleeve type double metal thermometer

                  5熱(re)套(tao)式雙(shuang)金(jin)屬溫(wen)度計.jpg
                  • 5熱套式雙(shuang)金屬溫度(du)計(ji).jpg
                  WSS series Thermal sleeve type double metal thermometer Is a kind of field measurement for middle an…

                  Description:

                  Productoverview:
                  WSS series Thermal sleeve type double metal thermometer Is a kind of field measurement for middle and low temperature measuring instrument, can be used for direct measurement of gas, liquid, and vapor temperature. The thermometer from the design principle and structure of waterproof, anti-corrosion, explosion-proof, anti vibration, intuitive, easy reading, no mercury damage, durability and other characteristics. The measurement instrument can replace the other workers.
                  Two, work principle:
                  WSS series Thermal sleeve type double metal thermometer Is the principle of expansion work in varying degrees of temperature change when using two different metals. Industrial use of double metal thermometer main element is one with two or more metal sheet laminated together to form a multilayer metal sheet. In order to improve the measurement sensitivity of double metal thermometer, usually made of sheet metals of spiral shape. When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen. Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to.
                  Three, application:
                  WSS series Thermal sleeve type double metal thermometer With the installation of all kinds of casing, meet different pressure level requirements. Can be directly measured in various production processes within the range of -80-+500 DEG C liquid, steam and gas and solid surface temperature.
                  Four, main features:
                  1, the scene display temperature, convenient, safe and reliable, long life and other characteristics.
                  2, victims of mercury free, easy reading, strong shock.
                  3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
                  4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
                  Five, technical parameters:
                  The implementation of standards
                  JB/T8803-1998 GB3836-83.
                  Other parameters
                  Dial diameter: 60100150;
                  The accuracy level: (1, 1.5);
                  Thermal response time: less than 40S;
                  Protection grade: IP55;
                  Angle adjusting error: angle adjusting error should not exceed the range of 1.0%;
                  Return difference: double metal thermometer to the difference should be less than the absolute value of the basic error limit;
                  Repeatability: double metal thermometer repeatability limit should be less than the absolute value of basic error of 1/2.

                  Six, matters needing attention
                  1, can not be directly screw head;
                  2, the length of choice to choose the standard size close to the (integer multiples of 50mm);
                  3, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, the general recommended immersion length is greater than 100mm, 0-50 DEG C immersion length range is more than 150mm, to ensure the accuracy of measurement.
                  4, double metal thermometer should not be used to open the container medium temperature measurement.
                  In 5, storage, installation and transportation, should avoid collision protection tube, do not allow the protection tube bending change, but not the table when using the wrench.
                  6 regular inspection, under normal conditions of use should be. In general, every six months.
                  7, not allowed to work in the strong vibration environment, so as not to affect the double metal life, electric contact bimetallic thermometer is not allowed in the control loop vibration occasions, so as not to affect the reliability.

                  Seven, temperature range:

                  The measuring range of C

                  Applicable scope

                  Industrial and commercial

                  Laboratory and small

                  -80 ~ +40

                  B.

                  B.

                  -40 ~ +80

                  B.

                  B.

                  0~50

                  B.

                  B.

                  0~100

                  B.

                  B.

                  0~150

                  B.

                  B.

                  0~200

                  B.

                  B.

                  0~300

                  B.

                  B.

                  0~400

                  B.

                  B.

                  0~500

                  B.

                  B.

                  Eight, dimensions:

                  form

                  D

                  A

                  B

                  E

                  D

                  Radial type

                  One hundred and five

                  Twenty-three

                  Seventy-three


                  With 8

                  With 10

                  One hundred and fifty-five

                  Twenty-three

                  Seventy-three


                  Axial type

                  Sixty-five

                  Fifty

                  One hundred and ten

                  Thirty-four

                  One hundred and five

                  Fifty

                  One hundred and ten

                  Thirty-four

                  Universal type

                  One hundred and five

                  Twenty-three

                  One hundred and seventy-eight

                  One hundred and twenty

                  One hundred and fifty-five

                  Twenty-three

                  One hundred and seventy-eight

                  One hundred and twenty

                  Electric contact

                  Axial type

                  One hundred and twenty-eight

                  Forty

                  One hundred and thirty-five


                  Electric contact

                  Radial type

                  One hundred and twenty-eight

                  Seventy-two

                  One hundred and fifty

                  Forty-two

                  Electric contact

                  Universal type

                  One hundred and twenty-eight

                  Forty

                  One hundred and seventy-five

                  Ninety-eight

                  9, models and specifications:

                  Model

                  Measuring range

                  Precision grade

                  Protection tube material

                  Specifications

                  Nominal pressure

                  Casing form

                  WSS-403S

                  -80-+40

                  -40-+80

                  0-50

                  0-100

                  0-150

                  0-200

                  0-300

                  0-400

                  0-500

                  1, 5

                  1Cr18Ni9Ti

                   

                  Three hundred and four

                  Three hundred and sixteen

                  316L

                  Hastelloy C-276

                  Seventy-five

                  One hundred

                  One hundred and fifty

                  Two hundred

                  Three hundred

                  Less than 30MPa

                  Threaded connection

                  WSS-503S

                  WSS-413S

                  WSS-513S

                  WSS-483S

                  WSSX-413S

                  WSSX-483S

                  WSS-403L

                  150-40MPa

                  Flange type

                  WSS-503L

                  WSS-413L

                  WSSX-503L

                  WSS-483L

                  WSS-583L

                  WSSX-403L

                  WSSX-483L

                  Note: Zhongwei and double metal thermometer can be installed with a variety of casing, casing in thermal heat installation form installation casing;
                  The protection tube material according to ordering protocol: * said nominal pressure set according to flange pressure rating.

                  10, encoding selection:

                  Serial number

                  WSS


                  Double metal thermometer (Zhongwei control)

                  Dial diameter

                  -3


                  Phi 60

                  -4


                  Phi 100

                  -5


                  Phi 150

                  Dial form

                  Zero


                  The axial (straight)

                  One


                  Radial (angle)

                  Two


                  135 degrees to (an obtuse type)

                  Eight


                  Universal (angle adjustable type)

                  Fixed form

                  Zero


                  No fixed device

                  One


                  Movable external thread

                  Two


                  The movable internal thread

                  Three


                  Fixed thread

                  Four


                  Fixed flange

                  Five


                  Card set screw

                  Six


                  Sleeve flange

                  Type of protection

                  S

                  L

                  Heat (S for screw type and type L flange type)

                  W


                  Type of protection

                  F


                  Anti-corrosion type

                  The selection of examples:
                  Universal type double metal thermometer, dial diameter 100, temperature range of 0 to 400 DEG C, 1.5, M27 * 2 rotatablemale thread length 450mm, WSS-481, 0 ~ L=450, 400 C, M27 * 2, 1.5.

                  The design and selection of notes:

                  1, model;
                  2, precision grade;
                  3, temperature range;
                  4, fixed form;
                  5, the installation form of casing heat;
                  6, the inserted length.
                  Customer service service commitment:
                  1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
                  2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
                  3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
                  4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
                  5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


                  Browse:
                  Return To The Top

                  分亯(xiang)到:

                  ahcfH
                            1. <center></center>