1. <center></center>

                1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
                  0517-86918678
                  Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
                  Tel:0517-86918678
                  Fax:0517-86918679
                  Email:zhongweick@https://zghzyb.com
                  Post Encoding:211600

                  Thermocouple assembly.

                  17裝配(pei)式(shi)熱電(dian)偶.jpg
                  • 17裝配式熱(re)電偶.jpg
                  WRNWith thermocouple As a measurement of the temperature transmitter and usually display instrument …

                  Description:

                  Productoverview:

                  WRN With thermocouple As a measurement of the temperature transmitter and usually display instrument and record instrument and electronic regulator supporting the use of. It can be directly measured in various production processes from 0 to 1800 DEG C. the range of liquid, steam and gas and solid surface temperature.According to state regulations, thermocouple assembly production company according to the international standard IEC 30 - Platinum Division No. 6, 10 Platinum Rhodium Platinum, nickel chromium nickel silicon, nickel constantan etc..

                  Two, work principle:

                  WRN series of <strong> assembly type thermocouple</strong> electrodes by two different conductor materials. The working principle of two different components of the conductor ends by welding, forming a loop direct temperature measuring end call measurement end, terminal end call reference end. When there is temperature difference between the measuring terminal and a reference terminal, will produce thermal emf in the circuit, connected to display instrument, the instrument will indicate the corresponding temperature of the thermocouple electromotive force generated by the value of the.

                  WRN series <strong> thermocouple assembly</strong> of the thermoelectric power with the measuring end temperature rise, thermoelectric sizeonly withthermocouple conductor material and the temperature difference between the two ends of the length, diameter and thermal electrode without thermocouple assembly is mainly composed of a junction box, protection tube, insulation casing, terminals, power extremely basic structure, and in a variety of fixed device.

                  Three, main features:

                  1, simple assembly, convenient replacement;

                  2, the pressure spring type temperature sensing element, good anti vibration performance;

                  3, large range of temperature measurement;

                  4, high mechanical strength, good pressure resistance.

                  Four, technical parameters:

                  Product executive standard

                  IEC584

                  IEC1515

                  GB/T16839-1997

                  JB/T5582-91

                  Insulation resistance at room temperature:

                  When the environment temperature is 20 + 15 ~ C, the relative humidity is not more than 80%, the test voltage is 500 + 50V (DC) insulation >1000 resistor between.M electrode and outer tube.

                  Fifth, the measurement range and basic error limit:

                  Thermocouple type

                  Code

                  Graduation

                  measuring range

                  Basic error limit

                  Nichrome constantan

                  WRK

                  E

                  0-800 C

                  + 0.75%t

                  Nickel chromium nickel silicon

                  WRN

                  K

                  0-1300 C

                  + 0.75%t

                  13- platinum rhodium

                  WRB

                  R

                  0-1600 C

                  + 0.25%t

                  Platinum Rhodium 10 platinum

                  WRP

                  S

                  0-1600 C

                  + 0.25%t

                  30 platinum rhodium 6

                  WRR

                  B

                  0-1800 C

                  + 0.25%t

                  Note: t is the sense of temperature measured temperature component values (c) thermal inertia level

                  Thermal inertia level

                  Time constant (seconds)

                  Thermal inertia level

                  Time constant (seconds)

                  I

                  90180

                  III

                  10-30

                  II

                  30-90

                  IV

                  < 10

                  Nominal pressure thermocouple: generally refers to the static outer protective tube can withstand working temperature and pressure rupture.
                  Thermocouple: minimum insertion depth should be not less than 8-10 times the diameter of the protective sleeve (Frederick product exception)
                  Insulation resistance: when the ambient air temperature is 15-35 DEG C, relative humidity is less than 80% when the insulation resistance is more than 5 megohm (voltage 100V). With the splash proof junction box of the thermocouple, when the relative temperature is 93 + 3 DEG C, the insulation resistance of more than 500 billion euro (voltage 100V)
                  The insulation resistance of high temperature thermocouples under high temperature, the thermal electrode (including double type) and the insulation resistance between protection tube and double heat electrode (per meter) should be greater than the value specified under the table.
                  Sixth, code:

                  WRSpecificationsContent (Zhongwei control)


                  R
                  30- platinum rhodium 6
                  P
                  10- platinum rhodium
                  N
                  Nickel chromium nickel silicon
                  E
                  Nickel - chromium (chromium Constantan)
                  heat
                  electric
                  even
                  materialmaterial
                  -One
                  No fixed device
                  Two
                  Fixed screw type
                  Three
                  Movable flange
                  Four
                  Fixed flange
                  Five
                  A movable flange square form
                  Six
                  Fixed thread taper protection tube
                  Fixed formTwo
                  Splash proof
                  Three
                  Waterproof type
                  Four
                  Flameproof type
                  Connection boxZero16mm protection tube
                  One25mm protection tube (double casing)
                  Two16mm high aluminum tube (single tube)
                  Three20mm high aluminum tube
                  DesIgn Serial Number.
                  WR.-....
                  Seventh, design selection and ordering information:
                  Please provide the indexing number, precision grade, fixed form, protection material, length or depth of insertion tube (protective tube length L=l+150, special insertion depth and protection tube material can be ordered according to the agreement).
                  Customer service service commitment:
                  1, my company sold thermocouple series products in quality problems arise within twelve months, responsible for free maintenance.
                  2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
                  3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
                  4 after the warranty period, product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
                  5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, 48 hours outside users arrive at the scene.



                  Browse:
                  On A:Armored thermocouple
                  Next:No
                  Return To The Top

                  分亯到:

                  pifuf
                            1. <center></center>