                  Electric through single seat regulating valve

                  1電動直通單座調節閥.jpg
                  • 1電動直通單座調節閥.jpg
                  Electric through single-seat regulating valve is composed of DKZ series direct-stroke electric actua…

                  Description:

                  A brief introduction:
                  ZAZP seriesThrough single seat electric regulating valveThe DKZ series electric actuator and straight through single seat valve is composed of two parts, the single-phase AC 220V power supply for power, take 0 ~ 10mA or 4-20mA DC signal, automatic control valve opening, continuous adjustment of the fluid in the pipeline pressure, flow, level and other parameters of the.The product is sensitive, convenient and energy characteristics of fast signal transmission.Widely used in electric power, metallurgy, chemical industry, textile and other industrial automatic control system.
                  Two,Through single seat electric regulating valveThe material of main parts:

                  body materialMaterialNominal pressure (MPa)Suitable temperature range (c)
                  Room temperatureCooling type
                  cast ironHT200One point six-20~200-
                  cast steelZG230~4504, 6.4-40~250-40~450
                  Cast stainless steel
                  ZG1Cr18Ni9Ti
                  ZG0Cr18Ni12Mo2Ti
                  4.0, 6.4-40~250-60~450

                  Three,Through single seat electric regulating valveThe main technical parameters:

                  The nominal diameter of DN (mm)G3/4 "TwentyTwenty-fiveThirty-twoFortyFiftySixty-fiveEightyOne hundredOne hundred and twenty-fiveOne hundred and fiftyTwo hundred
                  The seat diameter of DN (mm)ThreeFourFiveSixSevenEightTenTwelveFifteenTwentyTwenty-sixThirty-twoFortyFiftySixty-sixEightyOne hundredOne hundred and twenty-fiveOne hundred and fiftyTwo hundred
                  Rated flow coefficient KvZero point zero eightZero point one twoZero point twoZero point three twoZero point fiveZero point eightOne point twoTwoThree point twoFiveEightTwelveTwentyThirty-twoFiftyEightyOne hundred and twentyTwo hundredTwo hundred and eightyFour hundred and fifty
                  Flow characteristicsstraight lineLinear, equal percentage
                  Nominal pressure PN (MPa)Ten1.6, 4, 6.4
                  Connection typePipe thread connection G3/4Flange connection: PN1.6 according to the standard of JB79-59; PN4.0 according to the JB79-59 standard
                  With the actuator modelDKZ-310DKZ-310DKZ-310DKZ-410DKZ-410
                  A pump thrust (N)Four thousandFour thousandFour thousandSix thousand and four hundredSix thousand and four hundred
                  Stroke L (mm)TenTenSixteenTwenty-fiveFortySixty
                  Total travel time (S)EightEightTwelve point fiveTwentyThirty-twoFifty
                  Mode of actionElectrical open (K) commonly used electric closed (B);
                  Input signal0~10mA 4~20mA DC
                  Power supply220V; 50~60Hz
                  The inherent adjustable ratio R30:1

                  Fourth, <strong> electric through single seat control valve</strong>  of the main technical performance index:

                  projectTechnical performance index
                  Basic error%Less than 5
                  Differential%Less than or equal to 3
                  Dead%Less than or equal to 5
                  Leakage0.01% * valve rated capacity
                  The rated flow coefficient error%Less than 10; when the KV is less than or equal to 6.3, is less than 15

                  Five, allow pressure:

                  The use of

                  The valve is open flow, close the valve after the pressure P2 = 0

                  Nominal diameter
                  DN (mm)

                  The seat diameter
                  DN (mm)

                  Actuator
                  Effective thrust
                  (N)

                  Allowable differential pressure (sMPa)

                  Through single seat electric regulating valve

                  PN1.6 (MPa)

                  PN6.4 (MPa)

                  3/4

                  Three

                  Four

                  Five




                  Six

                  Seven

                  Eight

                  Twenty

                  Ten

                  Twelve

                  Fifteen

                  Twenty

                  Forty billion ten million two thousand and five hundred

                  Nominal pressure

                  Three point eight

                  Two point seven

                  One point seven

                  One

                  Nominal pressure

                  4.34.3

                  Two point five

                  Twenty-five

                  Twenty-six

                  Forty billion ten million two thousand and five hundred

                  Zero point five

                  Nominal pressure

                  Zero point six

                  Three point six


                  Thirty-two

                  Thirty-two

                  Zero point four

                  Nominal pressure

                  Zero point four

                  Two point three


                  Forty

                  Forty

                  Four million and one thousand
                  Twenty-five million six thousand and four hundred

                  Zero point seven

                  One

                  Zero point seven

                  One point five


                  Fifty

                  Fifty

                  Zero point five

                  One

                  Zero point five

                  One


                  Design of ordering and selection of notes:
                  1, the product name and model of the products of the nominal diameter of pressure material by the use of the medium temperature and products with the attachment so that we provide you the correct selection.
                  2, if you have special request, please specify when ordering products in.
                  3, if the unit has been selected by the design model, please press the model directly to our sales department order.
                  4, the occasion is very important when using more complex or the environment when you try to provide design drawings.


                  Browse:
                  Return To The Top

                  分亯到:

                  RVyec
                            1. <center></center>