1. <center></center>

                1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

                  Nozzle flowmeter

                  23噴嘴流量計01.jpg
                  23噴嘴流量計03.jpg
                  • 23噴嘴流量計01.jpg
                  • 23噴嘴流量計03.jpg
                  ZW series of LGPNozzle flowmeterHas a long history background, all kinds of test data is complete.Si…

                  Description:

                  Products overview:

                  ZW series of LGPNozzle flowmeterHas a long history background, all kinds of test data is complete.Simple structure, no moving parts, stable and reliable long-term use, rich experience in design and manufacture and application.Doesn't need a high degree of standardization, solid flow calibration.Standard orifice has reliable experimental data and improve the international and national standards.In foreign countries and has its inherent in the huge domestic market, users are familiar with, data;Follow the international standard calculation and processing, use agile and convenient;The most widely used in domestic flow measurement is still the differential pressure type flowmeter.

                  Nozzle with high temperature and high pressure resistance, impact resistance, long service life, large measuring range and accuracy of measurement, suitable for high power plant high temperature and high pressure steam heat-supply pipeline flow of fluid flow measurement.Standard nozzle design and manufacture according to GB/T2624-93, according to JJG640-94 verification, without real flow calibration.

                  Second, the working principle:
                  ZW series of LGPThe principle is to use the throttle nozzle flowmeter flow sensor.It adopt special on the basis of the nozzle pressure (pressure) throat way, make the flow sensor not only has the advantages of traditional long neck nozzle, at the same time also have outflow coefficient of stability, repeatability of higher unique advantages.Is a kind of high precision flow sensor.Flow calculation formula:

                  Type: - mass flow respectively (㎏ / s) and the volume flow (m3 / s);
                  - flow coefficient;
                  - expansiveness coefficient;
                  -- the throttle hole diameter, m;
                  - diameter ratio,
                  - pipe diameter, m;
                  - the flow volume density, ㎏ / m;
                  -- differential pressure, Pa;

                  By measuring the pressure difference to measure the size of the fluid flow.This kind of measurement method based on the energy conservation law and the law of flow continuity as a benchmark.Fluid filled with pipes, when they flow through the pipe of the throttle device, a beam will local contraction at the throttling of the throttle device, so that the flow velocity increases, the static pressure is low, so the throttling parts before and after the pressure drop is produced, the pressure difference, the greater the flow of medium flow, on the throttling the greater the pressure difference before and after.
                  Applications:
                  ZW series of LGPNozzle flow meter is to measure flow differential pressure generator, cooperate with all sorts of differential pressure gauge or differential pressure transmitter to measure all kinds of fluid flow in pipes.Standard nozzle throttling device with differential pressure transmitter, can measure the rate of flow of liquid, steam, gas, widely used in petroleum, chemical, metallurgical, power, light industry and other departments.Measured medium is as follows:

                  1, liquid: hot and cold water, chemical liquid, light body oil.
                  2, gas, blast furnace gas, coke oven gas, all kinds of single-component multicomponent gas.
                  3, superheated steam and saturated steam.
                  4, compressed air.
                  5, natural gas, the torch gas, liquefied petroleum gas.

                  Four, the main features:

                  1, the throttle device structure easy to copy, simple, firm, stable and reliable performance, long service life, low price.
                  2, nozzle adopt international standards and processing
                  3, nozzle application range is wide, all single-phase flow are measured, partially miscible flow can also be applied.
                  4, standard throttle device without real flow calibration, putting-in-service proactively.
                  5, using imported monocrystalline silicon intelligent differential pressure sensor
                  6, high precision, perfect the self-diagnosis function
                  7, the intelligent standard nozzle intelligent orifice flowmeter range can be adjusted from the programming.
                  8, intelligent standard nozzle can be displayed at the same time the cumulative flow and transient flow, pressure, temperature.
                  9, have the functions of online, dynamic full compensation, intelligent orifice plate flowmeter has since diagnosis, set range.

                  Five, the technical parameters:

                  1, the nominal diameter: 20 mm or less DN 630 mm or less;
                  2, nominal pressure: PN acuities were 32 mpa;
                  3, working temperature: - 50 ℃ or less t 550 ℃ or less;
                  4, Reynolds number range: 0.30 beta 0.44 or less, or less 70000 ReD 107 or less or less;
                  0.44 beta 0.8 or less, or less 20000 ReD 107 or less or less;
                  5, throat diameter ratio: 0.30 beta 0.80 or less or less;
                  6, precision: 0.5, 1.0, 1.5, 2.0;
                  7, the reference standard: GB/T2624-2006, JJG640-94;
                  8, connection mode: flange, welding.

                  Six, orifice plate and nozzle flowmeter are two different types of differential pressure type flowmeter:
                  1, the nozzle flow meter
                  Advantages: long neck nozzle has a long history, there are a large number of all kinds of test data, the nozzle flow meter has simple structure and firm, no moving parts, stable and reliable long-term use, rich experience in design and manufacture and application, high degree of standardization, can need not to flow calibration.Standard nozzle has reliable experimental data and improve the international and national standards.Authentic measurement data, can be used as a trade settlement measurement table.
                  Disadvantages: manufacturing complex, the unit price is higher.
                  2, the orifice plate
                  Orifice meter advantages: high cost performance.Standard orifice plate has a long history, the international and national standards and verification regulations and a large number of experimental data, without real flow calibration.Authentic measurement data, can be used as a trade settlement measurement table.
                  Faults: orifice acute Angle edge wear, dirt and other factors will affect measuring accuracy.Verification cycle short 6 to 12 months.
                  Seven, the structure form:
                  Nozzle flowmeter by part A, perpendicular to the axis of the entrance surface of circular arc form surface B and C part and shrinkage of the entrance of the cylindrical throat E and protection of the edge of to prevent damage to the groove of F, its take pressure way upstream pressure mouth Angle of using access, downstream take pressure can be set up by the pressure of Angle joint, also can be set up in the far downstream.The total length of the nozzle
                  A, when 0.30 beta 2/3 or less or less, the nozzle length = 0.6041 d.
                  B, when two-thirds beta 0.80 or less or less, the nozzle length = {0.4041 + (0.75 / beta 0.25 beta 2-0.5225) 0.5} d;
                  C, ISA 1932 nozzle upstream face by perpendicular to the axis plane and profile for the two arcs of a circular, cylindrical throat and groove for the identified contraction of the nozzle.ISA1932 nozzle way of selecting pressure Angle only pressure a pick up.
                  Eight, notable matters of installation:
                  1, can be horizontal, vertical or inclined installation, should guarantee the tube filled with liquid.
                  2, the throttle device before and after the straight pipe should be straight, bend without visible to the naked eye, at the same time, should be "round", inner surface should be clean, without potholes and sediment;
                  3 and the request of straight section length and throttling device installation should be in conformity with the relevant provisions of the GB/T26224-93.
                  4, lead pressure pipeline installation should comply with the standards stipulated by the regulations.

                  Nine, scope of application and characteristics:

                  Throttling a name

                  Apply pipe

                  (DN mm)

                  Apply to diameter ratioB(d/D)

                  Application characteristics

                  Uncertainty of outflow coefficientEc%

                  Design criteria

                  Angle of access standard orifice plate

                  Ring chamber type

                  50-500

                  50-500

                  0.2-0.75

                  0.2-0.75

                  Apply to clean mediumGDUnder the condition of structure is suitable for high temperature and high pressure flow rate measurement

                  0.6-0.75%

                  ISO5167

                  GB/T2624-93

                  The clamping ring type

                  50-500

                  0.2-0.75

                  Easy to remove dirt, and can be used to clean fluid flow measurement

                  Oblique hole type

                  450-1000(3000)

                  0.2-0.75

                  Flange pressure standard orifice plate

                  50-1000

                  0.2-0.75

                  Easy to remove dirt, and are suitable for all kinds of media

                  0.6-0.75%

                  ISO5167

                  GB/T2624-93

                  Span with standard orifice plate

                  50-1000

                  0.2-0.75

                  Angle access standard pressure nozzle

                  (ISA1932Nozzle)

                  50-500

                  0.3-0.8

                  Small pressure loss, long life, especially suitable for steam flow measurement

                  0.8-1.2%

                  ISO5167

                  GB/T2624-93

                  The length to diameter nozzle

                  50-630

                  0.2-0.8

                  Small pressure loss of long service life,LGPType of length to diameter nozzle components for high parameters of water and steam flow measurement

                  2.0%

                  ISO5167

                  GB/T2624-93

                  Classic venturi tube

                  Mechanical processing type

                  100-800

                  0.2-0.8

                  The pressure loss is small, straight pipe required less than orifice, nozzle

                  1.0%

                  ISO5167

                  GB/T2624-93

                  Soldering iron plate type

                  200-1200(2000)

                  0.4-0.7

                  1.5%

                  Venturi nozzle

                  65-500

                  0.316-0.77

                  Same as above

                  1.2-1.75%

                  ISO5167

                  GB/T2624-93

                  A quarterRound hole plate

                  25-150

                  0.245-0.6

                  Suitable for low Reynolds number

                  2.0-2.5%

                  DIN BS

                  Conical inlet orifice

                  25-250

                  0.1-0.316

                  Same as above

                  2.0%

                  BS

                  Segmental orifice

                  50-1500

                  0.32-0.8

                  Apply to the smudges, there are air bubbles or containing solid particles flow measurement.

                  1.5%

                  DIN

                  The eccentric orifice plate

                  100-1000

                  0.46-0.84

                  1-2%

                  ASME

                  Small hole plate

                  12.5-40

                  0.2-0.75

                  Applicable to small pipe flow measurement

                  0.75%

                  ASME

                  Lens type orifice

                  12.5-150

                  0.2-0.75

                  Suitable for high pressure temperature small pipe flow measurement

                  0.6-0.75%

                  ISO5167ASME

                  Ten, classification model parameter table:

                  The name of the

                  model

                  Take pressure way

                  Nominal pipe diameter (mm)

                  Nominal pressure (MPa)

                  Execution standard (structure)

                  The standard orifice plate

                  LGB

                  Pressure Angle joint (annulus)

                  50~400

                  Less than10

                  GB2624 K07

                  LGB-Z

                  Pressure Angle joint (drilling)

                  400~2000

                  Less than1.6

                  LGB

                  Ring chamber (8 slot)

                  50~400

                  Less than32

                  The flow measurement manual

                  LGB

                  Ring room (no flange welded)

                  50~275

                  Less than28.22

                  The flow measurement manual

                  LGB-F

                  The flange to take pressure

                  50~800

                  Less than2.5

                  GB2624 K06

                  LGB-F

                  The flange to take pressure

                  50~400

                  4.0~40

                  GB2624 K06

                  LGB-J

                  Diameter of pressure

                  50~760

                  Less than10

                  GB2624

                  Standard nozzle

                  LGP

                  Pressure Angle joint (annulus)

                  50~400

                  Less than10

                  GB2624

                  The flow measurement manual

                  LGP-Z

                  Pressure Angle joint (drilling)

                  400~500

                  Less than1.6

                  LGP

                  Ring chamber (8 slot)

                  50~300

                  Less than32

                  The flow measurement manual

                  LGP

                  Ring room (high pressure lens pad)

                  15~150

                  Less than32

                  LGP

                  Ring room (no flange welded)

                  175~350

                  Less than17.36

                  DG 0702~0710

                  The length to diameter nozzle

                  LGC-J

                  Diameter of pressure

                  50~630

                  Less than16

                  GB2624

                  A quarterRound hole plate

                  LGH

                  Take pressure Angle joint

                  50~260

                  Less than10

                  GB2624

                  The flow measurement manual

                  LGH-F

                  The flange to take pressure

                  50~200

                  Less than6.4

                  Venturi nozzle

                  LGL

                  Take pressure Angle joint

                  65~500

                  Less than2.5

                  Venturi tube

                  LGW

                  Take special pressure

                  50~1200

                  Less than2.5

                  Double venturi tube

                  LGW-S

                  Take special pressure

                  Less than1000

                  Less than0.6

                  Small diameter orifice

                  LGX

                  Take pressure Angle joint

                  12~40

                  Less than6.4

                  K07(LanHua)

                  LGX-F

                  The flange to take pressure

                  12~40

                  Less than6.4

                  The enterprise standard

                  High pressure lens gasket

                  LGT

                  Take pressure Angle joint

                  50~150

                  Less than32

                  The flow measurement manual

                  Segmental orifice

                  LGQ

                  Pressure Angle joint (annulus)

                  100~400

                  Less than1.6

                  LGQ-Z

                  Pressure Angle joint (drilling)

                  400~1000

                  Less than1.6

                  LGQ-F

                  The flange to take pressure

                  100~350

                  Less than6.4

                  Double orifice

                  LGS

                  Take pressure Angle joint

                  100~400

                  Less than6.4

                  The eccentric orifice plate

                  LGN

                  Take pressure Angle joint

                  100~1000

                  Less than6.4

                  Current limit orifice

                  LG-XL


                  10~300

                  Less than6.4

                  The enterprise standard

                  Conical inlet orifice

                  LGR

                  Take pressure Angle joint

                  25~1000

                  Less than10

                  GB2624

                  The wing wind device

                  LJY

                  Take special pressure

                  Less than1000

                  Less than0.6

                  The enterprise standard

                  Eleven, selection of coding:

                  model

                  said Ming

                  ZW-LG

                  The throttle device (wei measurement and control)


                  Code name

                  According to the structure characteristics of the two basic categories


                  B

                  The standard orifice plate


                  P

                  Standard nozzle


                  Code name

                  Nominal pressure (105Pa)


                  2.5

                  2.5


                  10

                  10


                  16

                  16


                  25

                  25


                  64

                  64


                  100

                  100


                  200

                  200


                  Code name

                  CAL(mm)


                  15~1200

                  15~1200mm


                  Code name

                  According to its structure form of segmentation


                  H

                  The standard orifice plate(Ring chamber)


                  Y

                  The standard orifice plate(The flange)


                  K

                  The standard orifice plate(drilling)


                  I

                  ISA 1932The nozzle


                  L

                  The length to diameter nozzle


                  W

                  Venturi nozzle


                  G

                  Classic venturi tube


                  S

                  Double orifice


                  Q

                  Segmental orifice


                  Z

                  Conical inlet orifice


                  R

                  A quarterRound hole plate


                  P

                  The eccentric orifice plate


                  N

                  As a whole(Hidden within)Orifice plate


                  X

                  Wedge orifice


                  T

                  Out of place in the above special throttling device


                  Code name

                  medium


                  1

                  liquid


                  2

                  gas


                  3

                  steam


                  4

                  High temperature liquid


                  Code name

                  Compensation in the form of


                  N

                  Without pressure and temperature compensation


                  P

                  With pressure compensation output


                  T

                  With temperature compensation output


                  Q

                  With compensation output pressure and temperature


                  Code name

                  Differential pressure transmitter range scope


                  0

                  Micro differential pressure range


                  1

                  Low differential pressure range


                  2

                  The differential pressure range


                  3

                  Elevation difference pressure range


                  Code name

                  Whether or not to bring a live show


                  W

                  The throttle device sensors


                  X

                  Intelligent throttling device

                  13 order, design notes:

                  When you place an order, please provide the following conditions in order to help the correct choice of the specifications of the flowmeter and coefficient.

                  1, pipe size: diameter x wall thickness (mm);

                  2, measuring medium name: medium density (kg/m3);

                  3, set the flow range: meter range of upper limit and lower limit (kg/h or m3 / h);

                  5, work pressure (Mpa);

                  6, work temperature: (° C);

                  7, such as wei in my company, please provide together: intelligent flow totalizer.especially pressure range, or pressure transmitter type, range;Temperature range, or models, range temperature transmitter.

                  After-sales service commitment:

                  1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

                  2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

                  3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

                  4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.


                  Browse:
                  Return To The Top

                  分亯到:

                  ivEXo
                            1. <center></center>